Incident: Bombardier Inc CL 600 2B19
Jan 23, 2017 · Baltimore, MD
NTSB numberENG17IA008Event id20170124X45041
- 0
- Fatalities
- 0
- Serious injuries
- 0
- Minor injuries
- 51
- Uninjured
Probable cause
A Bombardier CRJ200 No. 2 engine failure due to the separation of a fan blade airfoil at a low cycle fatigue crack that originated at the forward fan blade pin hole attachment. The separated fan blade had previously undergone a hot form repair and both metallurgical analysis and repair records indicated that the lance/shot peen step required to restore sufficient residual stress levels to the blade material was not completed.
Source: National Transportation Safety Board. Record last changed Oct 28, 2026, 10:54 UTC.
Aircraft involved
- Aircraft
- Bombardier Inc CL 600 2B19
- Registration
- N8986B
- Year built
- 2004
- Category
- Airplane
- Operating rules
- Part 121: air carrier
- Defining event
- Enroute-climb to cruise Powerplant sys/comp malf/fail
Source: National Transportation Safety Board aviation accident database. Counts only; Voydar holds no names.
Nearest airports
Airports with a Voydar profile closest to the recorded position. Proximity only.
- Baltimore/Washington International Thurgood Marshall Airport (BWI)0 nm (0 km) south
- Fort Meade Executive Airport (FME)7 nm (13 km) south-west
- Martin State Airport (MTN)15 nm (27 km) north-east
This page restates the NTSB's public record. Injury figures are counts; Voydar does not hold or publish the names of anyone involved.